More in Ophthalmics:
Hydrophobic Lenses
Hydrophobic IOL are made from material having unique posterior edge design without compromising inherent optical properties of intra ocular lens.
High index of refraction imparts excellent folding prior to insertion; better, controlled unfolding and positioning of lens in the eye. Minimal internally reflected glare, less surface scattering compared to other hydrophobic surface IOLs. Incision size i.e sub 2.8mm.
High Tensile Strength - this resists the optic damage during folding and insertion.
Our entire Hydrophobic IOL Portfolio can be manufactured in 0° angulation under special order requirement
Hydrophobic Aspheric
Natural Yellow Hydrophobic Aspheric
Features:
- Asphericity on anterior surface of the IOL.
- Optic is having negative spherical aberration to compensate positive spherical aberration of cornea.
- 360° Advanced Square Edge.
- Enhanced contrast sensitivity, sharpness and clarity at night.
- Smooth lens surface reduces bacterial adhesion and inflammatory cell response
Advanced Aspheric IOLs with excellent visual outcomes:
| Property | Technical Specification |
| Model | ASHFY600 |
| Type | Single Piece |
| Material | Natural Yellow Hydrophobic Material |
| Refractive Index | 1.483 |
| Optical Shape | Biconvex |
| Optical Diameter | 6.0 mm |
| Overall Length | 12.5 |
| Angulation | 5° |
| Estimated A Constant | 118.5 |
| ACD | 5.28 mm |
| Power Range | From +5.0D to +30.0D (by 1/2 diopter from +15.0D to +25.0D) |
| Sterilization | By ETO Sterilization |
| Indication | Phacoemulsification |
| Implantation | Capsular Bag |
Below: Transmission scan shows blue light blocking property (in region 400 - 500nm) compared to conventional IOL with UV absorber. ![]() | |
Conventional IOLs with UV absorber are not able to protect the retina from dangerous high energy blue light. High energy blue light is a part of visible light spectrum which has great role in formation of age related Macular Degeneration (AMD).
Eyecryl Plus Natural Yellow hydrophobic IOL has a cross linked blue light filter in addition to UV aborber. Protective properties of these lenses resemble those offered by natural human lens.
These lenses demonstrate excellent visual outcomes without altering the colour perception and contrast sensitivity of a patient.
These lenses demonstrate excellent visual outcomes without altering the color perception and contrast sensitivity of a patient.
High index of refraction:
High index of refraction imparts excellent folding prior to insertion; better, controlled unfolding and positioning of lens in the eye; minimal internally reflected glare; less surface scattering compared to other hydrophobic IOLs; thinner lens which requires smaller incision i.e. Sub 2.8 mm.
High Tensile Strength:
This resists optic damage during folding and insertion
Excellent cytological and biocampatible properties:
- Effect on the blood aqueous barrier: Biotech Hydrophobic Lens is recommended in patients with pathologies predisposing to blood aqueous barrier damage
- The cellular reaction on the lens surface: 360° Sq. edge design reduces potential for lens epithelial cell migration on to posterior capsule. Eyecryl Plus hydrophobic lens has Minimal affinity towards lens epithelial cell outgrowth and slow maturaton rate reaction of macrophages providing excellent biological compatibility thus leads to a little or nil inflammatory reaction
- Effect on the lens capsule: The effect of the IOL on the capsule consists of lens epithelial cell proliferation and metaplasia leading to anterior and posterior capsular opacification , and IOL decentration. Eyecryl Plus Hydrophobic Lens has excellent capsular biocompatibiliy (because of the tacky nature of lens material the lens has increased adhesion of the IOL to The capsule) than hydrophillic material and decreased incidents of PCO and IOL decentration.
Clear Hydrophobic Aspheric
Features:
- Asphericity on anterior surface of the IOL.
- Aberration free optic.
- 360° Advanced Square Edge.
- Enhanced contrast sensitivity, sharpness and clarity at night.
- Exact refractive value of the IOL is printed along with diopter on the box to facilitate the surgeon to choose nearest diopter that matches to A-Scan biometry result.
- Smooth lens surface reduces bacterial adhesion and inflammatory cell response.
Advanced Aspheric IOLs with excellent visual outcomes:
| Property | Technical Specification |
| Model | ASHF600 |
| Description | Hydrophobic Aspheric |
| Type | Single Piece |
| Material | Clear Hydrophobic Material |
| Refractive Index | 1.483 |
| Optical Shape | Biconvex |
| Optic Diameter | 6.0 mm |
| Overall Length | 12.5 |
| Haptic Type | "C" Loop |
| Angulation | 5° |
| Estimated A Constant for Ultrasound Biometry | 118.5 |
| Estimated A Constant for IOL Master | 120 mm |
| Incision size required | 2.2 mm |
| Delivery System | Disposable Injector and Cartridge |
| ACD | 5.28 mm |
| Power Range | From +5.0D to +30.0D (by ½ diopter from +15.0D to +25.0D) |
| Sterilization | By ETO Sterilization |
| Indication | Phacoemulsification |
| Implantation | Capsular Bag |

Hydrophobic Lens
Natural Yellow Hydrophobic IOLs
Specifications:
| Property | Technical Specification |
| Model | HFY 600 |
| Type | Single Piece |
| Description | Natural Yellow Hydrophobic |
| Material | Hydrophobic |
| Refractive Index at 20° | 1.485 |
| Optical Diameter | 6.0 mm |
| Overall Length | 12.5 |
| Angulation | 5° |
| Estimated A Constant | 118.5 |
| Haptic Type | "C" Loop |
| Estimated A Constant for Ultrasound Biometry | 118.5 |
| Estimated A Constant for IOL Master | 120 mm |
| Incision size required | 2.2 mm |
| Delivery System | Disposable Injector and Cartridge |
| Edge Type | 360° Square Edge |
| Power Range | From +5 to +30.0D ( ½ range from 5 to 25D) |
| ACD | 5.28 mm |

Clear Hydrophobic IOLs
Specifications:
| Property | Technical Specification |
| Model | HF 600 |
| Type | Single Piece |
| Description | Clear Hydrophobic Acrylic CQ UV |
| Material | Hydrophobic |
| Refractive Index at 20° | 1.485 |
| Optical Diameter | 6.0 mm |
| Overall Diameter | 12.5 |
| Angulation | 5° |
| Estimated A Constant | 118.5 |
| Haptic Type | Optimised "C" |
| Estimated A Constant for Ultrasound Biometry | 118.5 |
| Estimated A Constant for IOL Master | 120 mm |
| Incision size required | 2.2 mm |
| Delivery System | Disposable Injector and Cartridge |
| Edge Type | 360° Sq Edge |
| Power Range | From +5 to +30.0D |
| ACD | 5.28 mm |