More in Ophthalmics:
Hydrophilic Lenses
Our single piece, foldable acrylic lenses are available with open and closed haptic designs, optimized "C" shape for optimized contact with the capsular bag. A product profile is developed to yield attributes desired for a foldable lens material. These attributes include optical for clear post surgical vision, mechanical for easy handling for the surgeon and toxicological properties making the lens non-irritating to surrounding tissues after implantation. A range of models are available for acrylic foldables in increments of 0.5 diopter. Foldable acrylic lens can be supplied with holder folder for ease of handling during surgery.
Our entire Hydrophilic IOL Portfolio can be manufactured in 0° angulation under special order requirement
Eyecryl Plus: Aspheric, Accomodative & MicroThin Hydrophilic IOLs
EYECRYL PLUS ™ (Clear Aspheric with Hydrophobic Surface Lens)
EYECRYL PLUS ™ (Clear Aspheric with Hydrophobic Surface Lens)
Hydrophobic Surface Acrylic Foldable IOL with Delivery System
Description: (design concept of aspheric IOL)
Conventional spherical IOLS have positive spherical aberrations resulting in decreased contrast sensitivity.
First generation aspherical IOLs have negative spherical aberrations. These IOLs are not universally acceptable because of higher order aberrations (HOAs) in case of decentration or tilting of lens.
Eyecryl Plus Aspheric Series IOLs are aberration free IOLs with aspheric anterior and posterior surfaces. The aberration free design provides good performance and vision even in case of zonular weakness, decentrated pupils and tilting of lens. (Eyecryl Plus Aspheric Series IOLs have been tested for +0.5 mm of decentration and 5 Degree of tilting). The visual function in mesopic/low light conditions improves drastically.
Diopter range - We offer a full range of available Diopter from - 20.00D to +50.00D, in 0.50d increments under Special Manufacturing.

As shown in the diagrams below, incase of Eyecryl Plus Aspheric Series IOL, the diopter remains uniform from central optical zone to the optical edge, whereas incase of conventional spherical IOL diopter shift is evident outside the central optical zone of 3.0 mm.
![]() | ![]() | |
Technical Specifications:
| Model | EYECRYL PLUS HSAS 600 | EYECRYL PLUS HSAS 4X4 |
| Lens Material | Foldable acrylate and UV-absorber | Foldable acrylate and UV-absorber |
| Refractive Index | 1.462 | 1.462 |
| Optic Size | 6.0 mm | 6.0 mm |
| Overall Size | 12.5mm | 11.0mm |
| A Constant | 118.0 | 118.0 |
| ACD | 4.96 | 4.96 |
| Angle | 5° | 5° |
| Diopter Range | +5 To 30 D | +5 To 30 D |
| Edge Type | 360° Square Eddge | 360° Square Eddge |
![]() | ||
Hydrophobic Surface Modification:
Surface modification offers a hydrophillic lens with surface properties similar to hydrophobic lens without changing the bulk properties of the IOL material.
The idea behind surface modification of Hydrophillic IOL is to make it more hydrophobic & render it less attractive to cell attachment and cell growth.
Hydrophollic acrylic material has a proven clinical history and acceptability within ophthalmic segment. We are providing a major advantage to this material by providing a permanent hydrophollic acrylic polymer.
Advantages of Surface modified IOLs:
- Surface which is permanent in nature & technology that has proven its effectiveness is many implantable medical devices
- Higher contact angle increases hydrophobicity
- Smooth lens surface prevents bacterial adhesion
- Lower surface energy inhibits cell growth & cell adherence thus postponing the secondary cataract
- Resistance to silicon oil adherence
- Reduced inflammatory cell response
- Optical Purity-no vacuoles
- High Biocompatibility
- Facilities placement of the lens and reduces trauma to the patient by allowing for a smaller incision during surgery
- Implantation withourt substantial risk of corneal endothelial cell damage
- Insensitive to atmospheric temperature changes as compared to hydrophobic IOLs
- Less attractive to airborn particles particles in operational field
- Cost effective
Contact Angle:
Hydrophobicity can be monitored by water contact angle measurement a sessible drop method (contact angle increases in case of surface modified IOLs). Contact angle prevails about 35° - 45° incase of conventional hydrophobic IOL, which increases up to 75° - 85° in case of surface modified hydrophobic IOL. Pictures of measuring contact angle are:

Refraction Value:
The Refraction value mentioned on the lens label is the actual value of measurement after all the manufacturing processes (including surface modification of hydrophobic lenses).
EYECRYL PLUS ™ (Natural Yellow Aspheric with Hydrophobic Surface Lens)
EYECRYL PLUS ™ (Natural Yellow Aspheric with Hydrophobic Surface Lens)
Hydrophobic Surface Modified

Advanced Aspheric IOLs with excellent visual outcomes:
| Model | YHSAS 600 | YHSAS 600 ROH | YHSAS 4x4 |
| Type | Single Piece | Single Piece | Single Piece |
| Material | Natural Yellow Hydrophillic Acrylic CQ UV | Natural Yellow Hydrophillic Acrylic CQ UV | Natural Yellow Hydrophillic Acrylic CQ UV |
| Water Content | 26 % | 26 % | 26 % |
| Refractive Index | 1.462 | 1.462 | 1.462 |
| Optical Shape | Biconvex | Biconvex | Biconvex |
| Optical Size | 6.0 mm | 6.0 mm | 6.0 mm |
| Overall Size | 12.5 mm | 12.5 mm | 11.0 mm |
| Angulation | 5° | 5° | 5° |
| Estimated A Constant | 118.0 | 118.0 | 118.0 |
| ACD | 4.96 | 4.96 | 4.96 |
| Power Range | From +5.0D to +30.0D (by 1/2 diopter from +15.0D to + 25.0D) | From +5.0D to +30.0D (by 1/2 diopter from +15.0D to + 25.0D) | From +5.0D to +30.0D (by 1/2 diopter from +15.0D to + 25.0D) |
| Sterilization | By Steam Sterilization | By Steam Sterilization | By Steam Sterilization |
| Indication | Phacoemulsification | Phacoemulsification | Phacoemulsification |
| Implantation Size | Capsular Bag | Capsular Bag | Capsular Bag |
Features:
- Hydrophobic Surface Modified IOL with Aspheric Optic
- Asphericity on Anterior surface of the IOL
- Aberration free optic
- 360 degrees Square Surface
- Enhances Contrast Sensitivity, Sharpness and Clarity at night
- Exact refractive value of the IOL is printed along with deopter on the box to facilitate the surgeon to choose nearest diopter that matches to A-Scan biometry result
- Optical Purity, No vacuoles
- Smooth lense surface reduces bacterial adhesion and inflamatort cell response
- Reduces PCO
With blue light filter - An optimal solution for retina protection
Eyecryl Plus Natural Yellow Series contains a unique covalently bound natural chromophore, which contains the same UV A blocking and Blue light Filtering chromophore that is in the human crystalline lens. We use nature's own solutions to the problem of protecting the retina from harmful energetic light. The absorption spectrum of 3 HydroxyKynurenine (Figure 1) shows that this natural compound is an excellent UV A blocker with a secondary purpose of filtering violet and blue light. This compound and its beta Glucoside derivatives are nature's primary protection for UV A and violet blue light.

We have made a special monomer identical to the naturally occurring chromophore and covalently incorporated it into our lens material. The visible transmission spectrum of our natural yellow lens material is shown below (Figure 2) compared to the transmission spectrum of a young human crystalline lens as defined by Van De Kraats and Van Norren1. Using nature's chromophore also provides natural protection while maintaining high contrast sensitivity.
Thus, Eyecryl Plus Natural Yellow Series provide blue light filtering similar to a young natural lens.

EYECRYL PLUS ™ (Natural Yellow Hydrophilic Lens)
EYECRYL PLUS ™ (Natural Yellow Hydrophilic Lens)

Advanced Aspheric IOLs with excellent visual outcomes:
| Model | Y 600 | Y 600 ROH | Y 4x4 |
| Type | Single Piece | Single Piece | Single Piece |
| Material | Natural Yellow Hydrophillic Acrylic CQ UV | Natural Yellow Hydrophillic Acrylic CQ UV | Natural Yellow Hydrophillic Acrylic CQ UV |
| Water Content | 26 % | 26 % | 26 % |
| Refractive Index | 1.462 | 1.462 | 1.462 |
| Optical Shape | Biconvex | Biconvex | Biconvex |
| Optical Size | 6.0 mm | 6.0 mm | 6.0 mm |
| Overall Size | 12.5 mm | 12.5 mm | 11.0 mm |
| Angulation | 5° | 5° | 5° |
| Estimated A Constant | 118.0 | 118.0 | 118.0 |
| ACD | 4.96 | 4.96 | 4.96 |
| Power Range | From -5.0D to +30.0D (by 1/2 diopter from +15.0D to + 25.0D) | From -5.0D to +30.0D (by 1/2 diopter from +15.0D to + 25.0D) | From -5.0D to +30.0D (by 1/2 diopter from +15.0D to + 25.0D) |
| Sterilization | By Steam Sterilization | By Steam Sterilization | By Steam Sterilization |
| Indication | Phacoemulsification | Phacoemulsification | Phacoemulsification |
| Implantation Size | Capsular Bag | Capsular Bag | Capsular Bag |
| Edge Type | 360° Square Edge | 360° Square Edge | 360° Square Edge |
EYECRYL PLUS ™ (Hydrophobic Surface Lens)
EYECRYL PLUS ™ (Hydrophobic Surface Lens)
Acrylic Foldable IOL with Delivery System
Description: (design concept of Hydrophobic Surface Modification)
Surface modification offers a hydrophillic lens with surface properties similar to hydrophobic lens without changing the bulk properties of the IOL material.
The idea behind surface modification of Hydrophillic IOL is to make it more hydrophobic and render it less attractive to cell attachment and cell growth.
Hydrophillic acrylic material has a proven clinical history and acceptability within Ophthalmic segment. We are providing a major advantage to this material by providing a permanent hydrophobic outer surface without changing the physiochemical and other typical properties of hydrophillic acrylic polymer.
Advantages of Surface modified IOLs:
- Surface which is permanent in nature and technology that has proven its effectiveness in many implantable medical devices
- Higher contact angle increases hydrophobicity
- Smooth lens surface prevents bacterial adhesion
- Lower surface energy inhibits cell growth and cell adherence thus postponing the secondary cataract
- Resistance to silicon oil adherence
- Reduced inflammatory cell response
- Optical Purity-no vacuoles
- High Biocompatilbility
- Facilities placement of the lens and reduces trauma to the patient by allowing for a smaller incision during surgery
- Implantation withourt substantial risk of corneal endothelial cell damage
- Insensitive to atmospheric temperature changes as compared to hydrophobic IOLs
- Less attractive to airborn particles particles in operational field
- Cost effective
Comparative Chart:
| Models | HS 600 | HS 600 ROH | HS 4X4 | HS MICRO |
| Optic Material | Foldable acrylate with hydrophobic surface and UV-absorber | Foldable acrylate with hydrophobic surface and UV-absorber | Foldable acrylate with hydrophobic surface and UV-absorber | Foldable acrylate with hydrophobic surface and UV-absorber |
| Refractive Index | 1.462 | 1.462 | 1.462 | 1.462 |
| Optic Size | 6.0 mm | 6.0 mm | 6.0 mm | 6.0 mm |
| Overall Size | 12. 5mm | 12. 5mm | 11. 0mm | 10.6mm |
| Haptics | Optimised "C" | Open Haptics | 4 Open Haptics | Plate Haptics |
| A Constant | 118.0 | 118.0 | 118.0 | 118.0 |
| ACD | 4.96 | 4.96 | 4.96 | 4.96 |
| Angle | 5° | 5° | 5° | 5° |
| Diopter Range | -5 To 30 D | -5 To 30 D | -5 To 30 D | -5 To 30 D |
Contact Angle:
Hydrophobicity can be monitored by water contact angle measurement a sessile drop method ( contact angle increases in case of surface modified IOLs). Contact angle prevails about 35 - 45 incase of conventional hydrophilic IOL, which increases up to 75 - 85 in case of surface modified hydrophillic IOL.

Refraction Value:
The refraction value mentioned on the lens label is the actual value of measurement after all the manufacturing processes (including surface modification of hydrophillic lenses).
EYECRYL PLUS ™ (Accommodative Hydrophobic Surface Lens)
EYECRYL PLUS ™ (Accommodative Hydrophobic Surface Lens)
Hydrophobic Surface Acrylic Foldable IOL with Delivery System
Description: (design concept of Accomodative IOL)
Since the evolution of cataract surgery, the ultimate goal of cataract surgeon has been to provide unaided, high quality vision for distance, intermediate and near objects including every point in between. Eyecryl Plus HSATF575 is an accommodative lens plus CTR with a revolutionary design which is based on Hemholtz's theory of accommodation and addresses the problem of pseudophakic presbyopia fully and satisfactorily.
This IOL allows implantation through a standard phacoemulsification incision of sub 2.6 mm. The six haptics design with anterior vaulting allows the lens to move accommodate, to focus on objects near, far and at all distances in between without any hysterisis. The posteriorly vaulted haptics ensure minimum adhesion to anterior subcapsular cells for a longer period to maintain accommodation effect.
As a unique feature, the gap between six haptics diminishes during capsular bag contraction process to form a continuous CTR to postpone PCO.
As shown in the diagram below, during normal conditions (far focus), the curvature (angle) of the lens is reduced by the flattened capsular bag membrane and enlarges the overall focal distances of lens. Accomodation is accomplished by contraction of the ciliary body and subsequent release in the resting tension of the zonular fibres by which the crystalline lens is suspended, resulting in anterior movement of the optic creating a change in focus. The curvature of the optic also increases during this process, providing further change in focus as shown in fig: 1.2 and fig: 1.3.
Estimated axial displacement will be 0.25 - 1.0 mm resulting in accommodation over 1.5D.

Accomodative + MF IOL
HSATF575 MF is an accommodative + Multifocal IOL, which provides accommodation by axial movement of the lens and pseudoaccomodation by multifocal rings. In addition to the accommodation upto 1.5 D (approx.) , 3.0 D diopter addition is provided by the near diopter zone.
Details:
- Central Ring 0 - 1.5 mm : far vision
- Annular Ring 1.5 - 2.3 mm : near vision
- Peripherry 2.3 - 5.75 mm : distance vision
Hydrophobic Surface Modification:
Surface modification offers a hydrophillic lens with surface properties similar to hydrophobic lens without changing the bulk properties of the IOL material.
The idea behind surface modification of Hydrophillic IOL is to make it more hydrophobic and render it less attractive to cell attachment and cell growth.
Hydrophillic acrylic material has a proven clinical history and acceptability within Ophthalmic segment. We are providing a major advantage to this material by providing a permanent hydrophobic outer surface without changing the physiochemical and other typical properties of hydrophillic acrylic polymer.
Technical Specifications:
| Model | HSA TF 575 | HSA TF 575 MF |
| Type | Monofocal | Multifocal |
| Material | Foldable acrylate with hydrophobic surface and UV-absorber | Foldable acrylate with hydrophobic surface and UV-absorber |
| Refractive Index | 1.462 | 1.462 |
| Optic Size | 5.75 mm | 5.75 mm |
| Overall Size | 10.2 mm | 10.2 mm |
| Haptics | Six Haptics | Six Haptics |
| Estimated A Constant | 117.1 | 117.1 |
| Angle | 10° (anterior vaulting) | 10° (anterior vaulting) |
| Diopter Range | 18 to 30 D | 18 to 26 D |
Advantages of Surface modified IOLs:
- Surface which is permanent in nature and technology that has proven its effectiveness in many implantable medical devices
- Higher contact angle increases hydrophobicitySmooth lens surface prevents bacterial adhesion
- Lower surface energy inhibits cell growth and cell adherence thus postponing the secondary cataract
- Resistance to silicon oil adherence
- Reduced inflammatory cell response
- Optical Purity-no vacuoles
- High Biocompatibility
- Facilitates placement of the lens and reduces trauma to the patient by allowing for a smaller incision during surgery
- Implantation without substantial risk of corneal endothelial cell damage
- Insensitive to atmospheric temperature changes as compared to hydrophobic IOLs
- Less attractive to airborn particles in operational field
- Cost effective
Contact Angle:
Hydrophobicity can be monitored by water contact angle measurement a sessile drop method ( contact angle increases in case of surface modified IOLs). Contact angle prevails about 35° - 45° incase of conventional hydrophillic IOL, which increases upto 75°° - 85° in case of surface modified hydrophillic IOL. Pictures of measuring contact angle are:

Refraction Value:
The refraction value mentioned on the lens label is the actual value of measurement after all the manufacturing processes (including surface modification of hydrophillic lenses).
EYECRYL PLUS ™ (Micro Thin Foldable Lens)
EYECRYL PLUS ™ (Micro Thin Foldable Lens)
Micro-Eyecryl Acrylic lens For Micro-Phaco Acrylic 25% CQ UV
We are among the few manufacturers producing over 1.5 million Intraocular Lenses per annum, with 70% of our capacity being utilised for the export market
MICRO-EYECRYL is our extremely thin, foldable, flexible, lens.
We have technology that allows the manufacture of lenses with powers of +10 D to +30 D, with a thickness of only 500-700 µm. The MicroThin Foldable technology is achieved by an evolutionary optic design and a unique manufacturing process. The lens is made from hydrophilic material similar to IOL materials already in the market.
Technical Specifications:
| Material | Acrylic 25% CQ UV |
| Refractive Index | 1.46 |
| Optical Shape | Biconvex |
| Type | Micro Incision IOL |
| Optical Diameter | 6.00 mm with "Fish Tail" back optical edge |
| Overall Diameter | 10.60 mm |
| Estimated A Constant | 118.0 |
| A.C. Depthh | 4.96 mm |
| Power Range (in diopter) | From +10.0 to +30.0 (by ½ diopter from +15.0 to +24.0) |
| Sterilisation | By Steam Sterilization |
| Indication | Phacoemulsification |
| Implantation Site | Capsular Bag |
Advantages:
- The basic advantage of the lens is that it is ultra-thin with no compromise of optical quality.
- A 6 mm optimised optic to reduce aberrations and thickness.
- A 10.6mm outer diametere to 'fit' in the bag at once.
- An optimised haptics shape to drive any vault backwards, if any.
- A 'fish-tail back' optical edge design.
Image below shows the micro-surgical procedure for Micro Eyecryl:

Eyecryl: Clear Foldable Hydrophilic IOLs
EYECRYL / Clearvision 600
EYECRYL / Clearvision 600
Foldable Acrylic for Phaco (Acrylic 26% CQ UV)
Technical Specifications:
| Material | Acrylic 26% CQ UV |
| Refractive Index | 1.462 |
| Optical Shape | Biconvex |
| Type | One piece IOL |
| Optical Diameter | 6.00 mm with "Fish Tail" back optical edge |
| Overall Diameter> | 12.50 mm |
| Vault | 5° |
| Estimated A Constant | 118.0 |
| A.C. Depth | 4.96 mm |
| Power Range (in diopter) | From -5.0 to +30.0 (by ½ diopter from +15.0 to +25.0) |
| Sterilisation | By Steam Sterilization |
| Indication | Phacoemulsification |
| Implantation Site | Capsular Bag |
![]() | |

EYECRYL / Clearvision 600-ROH
EYECRYL / Clearvision 600-ROH
Foldable Acrylic for Phaco (Acrylic 26% CQ UV)
Technical Specifications:
| Material | Acrylic 26% CQ UV |
| Refractive Index | 1.462 |
| Optical Shape | Biconvex |
| Haptic Type | Open Haptic |
| Type | One piece IOL |
| Optical Diameter | 6.00 mm with "Fish Tail" back optical edge |
| Overall Diameter | 12.5 mm |
| Vault | 5° |
| Estimated A Constant | 118.0 |
| A.C. Depth | 4.96 mm |
| Power Range (in diopter) | From -5.0 to +30.0 (by ½ diopter from +15.0 to +25.0) |
| Sterilisation | By Steam Sterilization |
| Indication | Phacoemulsification |
| Implantation Site | Capsular Bag |
EYECRYL 600 L
EYECRYL 600 L
Foldable Acrylic for Phaco (Acrylic 26% CQ UV)
Technical Specifications:
| Material | Acrylic 26% CQ UV |
| Refractive Index | 1.462 |
| Optical Shape | Biconvex |
| Type | One piece IOL |
| Optical Diameter | 6.00 mm with "Fish Tail" back optical edge |
| Overall Diameter | 13.50 mm |
| Vault | 5° |
| Estimated A Constant | 118.0 |
| A.C. Depth | 4.96 mm |
| Power Range (in diopter) | From -5.0 to +30.0 (by ½ diopter from +15.0 to +25.0) |
| Sterilisation | By Steam Sterilization |
| Indication | Phacoemulsification |
| Implantation Site | Capsular Bag |
![]() | |

EYECRYL 600 LMF
EYECRYL 600 LMF
Foldable Multifocal Acrylic for Phaco (Acrylic 26% CQ UV)
Technical Specifications:
| Material | Acrylic 26% CQ UV |
| Refractive Index | 1.462 |
| Optical Shape | Biconvex |
| Type | One Piece Multifocal IOL |
| Optical Diameter | 6 mm |
| Overall Diameter | 13.5 mm |
| Vault | 5° |
| Estimated A Constant | 118.0 |
| A.C. Depth | 4.96 mm |
| Power Range (in diopter) | From 18.0 to 24.5 (with 0.5 increment) |
| Sterilisation | By Steam Sterilization |
| Indication | Phacoemulsification |
| Implantation Site | Capsular Bag |

EYECRYL TP 600
EYECRYL TP 600 (Foldable Acrylics)
Foldable Multifocal Acrylic for Phaco (Acrylic CQ UV)
Technical Specifications:
| Material | Acrylic CQ UV |
| Refractive Index | 1.462 |
| Optical Shape | Biconvex |
| Heptic Type | Modified 'C' |
| Type | Three Piece IOL |
| Optical Diameter | 6.00 mm with "Fish Tail" back optical edge |
| Overall Diameter | 12.50 mm |
| Vault | 5° |
| Estimated A Constant | 118.0 |
| A.C. Depth | 4.96 mm |
| Power Range (in diopter) | From +1.0 to +30.0 D |
| Sterilisation | By Steam Sterilization |
| Indication | Phacoemulsification |
| Implantation Site | Capsular Bag |
| (Note: Also available with 13.00 mm overall diameter.) | |

EYECRYL 4 x 4 600
EYECRYL 4 x 4 600
Foldable Acrylic for Phaco (Acrylic 26% CQ UV)
Technical Specifications:
| Material | Acrylic 26% CQ UV |
| Refractive Index | 1.462 |
| Optical Shape | Biconvex |
| Type | One piece IOL |
| Optical Diameter | 6.00 mm with "Fish Tail" back optical edge |
| Overall Diameter | 11.0 mm |
| Vault | 5° |
| Estimated A Constant | 118.0 |
| A.C. Depth | 4.96 mm |
| Power Range (in diopter) | From -5.0 to +30.0 (by ½ diopter from +15.0 to +25.0) |
| Sterilisation | By Steam Sterilization |
| Indication | Phacoemulsification |
| Implantation Site | Capsular Bag |
![]() | |

Features and Comparative Analysis of different Eyecyrl Models
Features and Comparative Analysis
EYECRYL PLUS
Features:
- Allows implantation through sub 2.6 mm incision size
- Packed in medical grade, biocompatible double blister packaging
- Endotoxin level bellow 0.25 EU/IOL
Comparative Analysis of Different EYECRYL Models:
| Particulars | EYECRYL TP600 | EYECRYL 600, 600 ROH, 600 4x4, 600 LMF | MICRO EYECRYL |
| Incision size | 3.2 mm | 2.4 to 2.6 mm | 2 x 1.4mm |
| Type of Surgery | Standard Phaco with enlarging incision | Standard Phaco Surgery Side Port | Bimanual Micro Incision Cataract Surgery with enlarging incision upto 1.7 |
| Phaco tip to be used | Standard Phaco tip with sleeve | Standard Phaco tip with sleeve | Standard Phaco tip without sleeve |
| Placing of cartridge | Placing the tip of the cartridge through the incision in the Anterior Chamber | Placing the tip of the cartridge through the incision in the Anterior Chamber | To be placed facing the incision |
| Inject the lens | Inject the lens in the bag | Inject the lens which will automatically glide in the bag since there are no loops to unfold and hence no manipulation is required | Inject the lens through the Incision (or wound). Inject the lens in the Anterior Chamber and place it in the bag using manipulator |
| Injector | Mechanical Injector | Hydraulic Injector | Hydraulic Injector |
| Cartridge | Biomeca Cartridge (BMC 180) | BioHydro Cartridge with Silicon plunger (BHC 150) | BioHydromini Cartridge with Silicon plunger (BHMC 145) |
Packaging of different Eyecyrl Models
Packaging of different Eyecyrl Models
Packaging
Eyecryl PLUS is supplied in double blister pack to ensure that the outer surface of the inner blister/vial (containing product) remains sterile while usage of product. Please open the outer blister in sterile environment. Now open the blister / vial on the operation table.
Bio Holder Folder
The Holder-Folder made of Medical grade pre-oriented PEI material is specially designed to deliver foldable lenses with ease. It not only holds the lens during implant but also has a locking device which folds the lens, facilitating surgery.

Packaging of Eyecryl Acrylic Lenses