EyeCryl Models
 Eyecryl 600
 Eyecryl 600+
 Eyecryl 600-OH
  Eyecryl 4x4 600
  Eyecryl 4x4 Fit
 Eyecryl 600 L
 Eyecryl TP 600
 Eyecryl 600 LMF
 Comparative Analysis: Eyecryl


Foldable Intraocular Lens  / EYE
CRYL
-------------------------------------------------------------------------------------------------
Comparative Analysis of different EYECRYL models
-------------------------------------------------------------------------------------------------

EYE
CRYL 600
Foldable Acrylic for Phaco :: Acrylic 26% CQ UV


TECHNICAL SPECIFICATIONS
Material Acrylic 26% CQ UV
"In Situ" Refractive Index 1.462
Optical Shape Biconvex
Type One piece IOL
Optical Diameter 6.00 mm with "Fish Tail"
  back optical edge
Overall Diameter 12.50 mm
Vault
Estimated A Constant 118.0
A.C.Depth 4.96 mm
Power Range (in diopter) From -5.0 to +30.0
  (by ½ diopter from +15.0 to +25.0)
Sterilisation By Steam Sterilization
Indication Phacoemulsification
Implantation Site Capsular Bag

Top

-------------------------------------------------------------------------------------------------
EYE
CRYL 600-ROH
Foldable Acrylic for Phaco :: Acrylic 26% CQ UV


TECHNICAL SPECIFICATIONS
Material Acrylic 26% CQ UV
"In Situ" Refractive Index 1.462
Optical Shape Biconvex
Haptic Type Open Haptic
Type One Piece IOL
Optical Diameter 6.00 mm with "Fish Tail"
  back optical edge
Overall Diameter 12.50 mm
Vault
Estimated A Constant 118.0
A.C.Depth 4.96 mm
Power Range (in diopter) From -5.0 to +30.0
  (by ½ diopter from +15.0 to +25.0)
Sterilisation By Steam Sterilization
Indication Phacoemulsification
Implantation Site Capsular Bag

Top

-------------------------------------------------------------------------------------------------
EYE
CRYL 4 X 4 600
Foldable Acrylic for Phaco :: Acrylic 26% CQ UV


TECHNICAL SPECIFICATIONS
Material Acrylic 26% CQ UV
"In Situ" Refractive Index 1.462
Optical Shape Biconvex
Type One Piece IOL
Optical Diameter 6.00 mm with "Fish Tail"
  back optical edge
Overall Diameter 11.0 mm
Vault
Estimated A Constant 118.0
A.C.Depth 4.96 mm
Power Range (in diopter) From -5.0 to +30.0
  (by ½ diopter from +15.0 to +25.0)
Steriliation By Steam Sterilization
Indication Phacoemulsification
Implantation Site Capsular Bag

Top

-------------------------------------------------------------------------------------------------
EYE
CRYL 600 L
Foldable Acrylic for Phaco :: Acrylic 26% CQ UV


TECHNICAL SPECIFICATIONS
Material Acrylic 26% CQ UV
"In Situ" Refractive Index 1.462
Optical Shape Biconvex
Type One Piece IOL
Optical Diameter 6.00 mm with "Fish Tail"
  back optical edge
Overall Diameter 13.50 mm
Vault
Estimated A Constant 118.0
A.C.Depth 4.96 mm
Power Range (in diopter) From -5.0 to +30.0
  (by ½ diopter from +15.0 to +25.0)
Sterilisation By Steam Sterilization
Indication Phacoemulsification
Implantation Site Capsular Bag

Top

-------------------------------------------------------------------------------------------------
EYE
CRYL 600 LMF
Foldable Multifocal Acrylic for Phaco :: Acrylic 26% CQ UV

TECHNICAL SPECIFICATIONS
Material Acrylic 26% CQ UV
"In Situ" Refractive Index 1.462
Optical Shape Biconvex
Type One Piece Multifocal IOL
Optical Diameter 6.00 mm with "Fish Tail"
  back optical edge
Overall Diameter 13.50 mm
Vault
Estimated A Constant 118.0
A.C.Depth 4.96 mm
Power Range (in diopter) From 18.0 to 24.5
  (With 0.5 increment)
Sterilisation By Steam Sterilization
Indication Phacoemulsification
Implantation Site Capsular Bag

Top


  Comparative Analysis of Different EYECRYL Models


  PARTICULARS


  EYECRYL TP600

  EYECRYL 600, 600 ROH,
  600 4 X 4, 600 4 X 4 FIT,
  600 LMF, 600 L


  MICRO EYECRYL
 Incision size   3.2 mm  2.4 to 2.6 mm  2 x 1.4mm
 Type of Surgery  Standard Phaco
   with enlarging incision
 Standard Phaco Surgery
   Side Port
 Bimanual Micro Incision 
   Cataract Surgery
   with enlarging incision upto
   1.7
 Phaco tip to be used  Standard Phaco tip with
   sleeve
 Standard Phaco tip with
   sleeve
   Standard Phaco tip without     sleeve
 Placing of cartridge  Placing the tip of the
   cartridge through the
   incision in the
   Anterior Chamber
 Placing the tip of the
   cartridge through the
   incision in the
   Anterior Chamber
 To be placed facing
   the incision
 Inject the lens  Inject the lens in the bag  Inject the lens which will
   automatically glide in the
   bag since there are no
   loops to unfold and hence
   no manipulation is required
 Inject the lens through
   the Incision (or wound).
   Inject the lens in the
   Anterior Chamber and
   place it in the bag using
   manipulator
 Injector  Mechanical Injector  Hydraulic Injector  Hydraulic Injector
 Cartridge  Biomeca (BMC 180)  BioHydro BHC 150 Cartridge
   with Silicon plunger
 BioHydromini with Silicon
   plunger  (BHMC145) 

Top